Start a new projectContact us
Our services

Integrated energy and sustainability solutions for new and existing buildings.

Supporting better-performing, lower-carbon buildings from design through operation.

Sketch of a service wheel around your building: energy modelling, MLI Select and incentives, LEED and Zero Carbon, commissioning, energy audits, decarbonization

Services for every stage of a building's life

New developments and existing portfolios need different things. We organize our work around both.

01

New construction

Energy modelling, certification and commissioning for new buildings.

Energy modelling for OBC SB-10 and SB-12, Toronto Green Standard and NECBCMHC MLI Select scoring and incentive supportZBA, OPA and SPA energy studiesLEED and Zero Carbon Building certificationNet-zero and early-design optimization studiesNew construction commissioning (NCx)
02

Existing buildings

Energy audits, recommissioning and retrofit planning for existing buildings.

ASHRAE Level 1, 2 and 3 energy auditsRecommissioning and retro-commissioning (EBCx)Measurement and verificationEnergy benchmarking and EWRB reportingRetrofit roadmaps and incentive procurement (Enbridge, Save on Energy)Decarbonization and capital planning
New construction

How we work on a new build

Energy modelling, certification and commissioning for new buildings. Each step feeds the next, so decisions are made with numbers, not assumptions.

Six-step process: early design, energy model, code and incentives, construction, commissioning, verify and operate
New construction: energy modelling

What is building energy modelling?

An energy model is a computer simulation of a building that estimates its energy use hour by hour over a full year. It is built from the building’s geometry, envelope, mechanical and electrical systems, and local weather data.

We use energy modelling to show compliance with OBC SB-10 and SB-12, the Toronto Green Standard and NECB. We also use it for CMHC MLI Select and ACLP applications, and to compare design options during design.

Sketch of building inputs: envelope, glazing, HVAC, lighting and loadsBuilding inputs
EnvelopeGlazingHVACLighting & loads
Sketch of a simulation screenEnergy modelHourly performance simulation in DesignBuilder, EnergyPlus and OpenStudio.
Better decisions
Demonstrate complianceCompare design optionsOptimize energy, carbon and cost
Existing buildings: audits and recommissioning

Energy audits, recommissioning and retrofit planning for existing buildings.

Sketch of an existing building being audited, recommissioned and verified
01

Audit

ASHRAE Level 1, 2 and 3 audits: collect data, benchmark, inspect systems and build a costed list of measures.

02

Recommission

Retro-commissioning (EBCx) tunes controls, schedules and setpoints so existing equipment performs as designed, at low capital cost.

03

Verify and plan

Measurement and verification, EWRB reporting and incentive applications, feeding a decarbonization and capital plan.

Not sure where to start?

Send us the drawings or the utility bills. We will tell you what the building needs.

Talk to our team